Commit 05f9262c authored by mjoang's avatar mjoang

Fix a bug so that BSR will be triggered when RLC entity has data.

parent 1495c7a3
......@@ -1053,7 +1053,7 @@ nr_update_bsr(module_id_t module_idP, frame_t frameP,
uint8_t lcid;
uint8_t lcgid;
uint8_t num_lcid_with_data = 0; // for LCID with data only if LCGID is defined
uint16_t lcgid_buffer_remain[NR_MAX_NUM_LCGID] = {0,0,0,0,0,0,0,0};
uint32_t lcgid_buffer_remain[NR_MAX_NUM_LCGID] = {0,0,0,0,0,0,0,0};
int32_t lcid_bytes_in_buffer[NR_MAX_NUM_LCID];
/* Array for ordering LCID with data per decreasing priority order */
uint8_t lcid_reordered_array[NR_MAX_NUM_LCID]=
......@@ -1146,13 +1146,7 @@ nr_update_bsr(module_id_t module_idP, frame_t frameP,
either the data belongs to a logical channel with higher priority than the priorities of the logical channels
which belong to any LCG and for which data is already available for transmission
*/
if ((mac->
scheduling_info.LCID_buffer_remain[lcid] == 0)
/* or there is no data available for any of the logical channels which belong to a LCG */
||
(lcgid_buffer_remain
[mac->scheduling_info.LCGID[lcid]] ==
0)) {
{
bsr_regular_triggered = TRUE;
LOG_D(NR_MAC,
"[UE %d] PDCCH Tick : MAC BSR Triggered LCID%d LCGID%d data become available at frame %d slot %d\n",
......