1. 26 Mar, 2018 1 commit
    • Masayuki HARADA's avatar
      Fix ul scd problems. · feeac61b
      Masayuki HARADA authored
      ・Delete double BSR calculation.
      ・change TBS for mcs setting bit to byte.
      
      (cherry picked from commit 39cd022424ebe98c95be32cbb4127aa9d0e0ff3b)
      feeac61b
  2. 20 Mar, 2018 1 commit
  3. 16 Mar, 2018 2 commits
    • Haruki NAOI's avatar
      1f6f2de7
    • Cedric Roux's avatar
      bugfix: fix issue 285 - connect/disconnect multiple time · ba72043e
      Cedric Roux authored
      As reported by Emad Alizade:
      
          According to "Issue255 256 257 paging reesta release" that has been
          merged in develop version, we have a question: In rrc_eNB_free_UE()
          function only all ulsch related memory of user has been cleaned, but
          I think not only ulsch memory but also dlsch memory must be cleaned.
          I tested the latest develop version and with repetition UE attach-detach
          procedures we find that the dlsch memory has not been cleaned and after
          repeat this sequence (45 times) assertion with cause UE_id!=-1 (no free
          or exiting dlsch_context, dci_tools.c: fill_dci_and_dlsch() ) occurred
          and no UE will be attached to system.
      
      The fixes in this commit are from Emad Alizade.
      
      (cherry picked from commit 4b5b55649351b4fe3f46b35d4a533a7b778ccce0)
      
      # Conflicts:
      #	openair1/PHY/LTE_TRANSPORT/dlsch_coding.c
      #	openair2/LAYER2/MAC/eNB_scheduler.c
      #	openair2/RRC/LITE/rrc_eNB.c
      ba72043e
  4. 01 Mar, 2018 3 commits
  5. 28 Feb, 2018 3 commits
  6. 27 Feb, 2018 1 commit
    • Cedric Roux's avatar
      hotfix: clear DCI padding bits · 65a08ad7
      Cedric Roux authored
      The problem is the following (as reported by an user):
      
        "one UE is attached to OAI system. UE is near the antenna. Try to detach
        the UE and attach again. Repeat this procedure for 5-6 times. OAI system
        does not work and any the UE can not attach to this system. I use TEMS
        software and I can see MIB signaling on this UE but UE can not decode SIB1
        and SIB2."
      
      What happens is that the DCI for SIB1 and SIB2 is not cleared before
      use. That is the bits in the 'padding' field keep the values that were
      set before. If the structure has been used to transmit other DCIs
      (eg. for UEs) in the past, it may be reused with some of those bits set
      to 1. When receiving this DCI, the UE won't accept it because it
      gets some bits at 1 where it expects them to be 0.
      
      The short-term/quick solution is to clear the 'padding' field.
      A better solution would be to rewrite this part of the code,
      which is way too complicated for what it does. But this takes
      too much time.
      
      In dci.h the field 'dummy' of some structures was renamed to 'padding'.
      The fields 'padding32' and 'padding64' were also renamed to 'padding'
      for consistency.
      
      Some structures (DCI2B_1_5MHz_TDD, DCI2B_10MHz_FDD, DCI2D_1_5MHz_FDD,
      DCI2D_5MHz_FDD, DCI2D_10MHz_FDD) had a 'padding' field at the end, which
      was renamed to 'padding0'. I don't know if this field should be here at all.
      To me this field looks very suspicious. When we test DCIs 2B and 2D we
      should be careful.
      
      (cherry picked from commit c5ca2bd86227d958175f2a5569546c1d60179d07)