1. 31 Mar, 2021 3 commits
    • Cedric Roux's avatar
      x2: exit if connection between eNB and gNB breaks · 1894bdb2
      Cedric Roux authored
      Before this commit, when the gNB crashes, the eNB keeps running.
      Same, if the eNB crashes, the gNB keeps running.
      
      In a far past when this happened, the other program (the one not
      crashing) was forced to exit.
      
      Then this behavior was changed, for some reason.
      But the code was not finished, so now we have a system in an inconsistent
      state.
      
      So either we accept that the connection between eNB and gNB can break,
      that is one of the programs crashes, and we clean the state of the
      program that keeps running. But this is a complex work and it will
      surely not survive very long, because someone will change something
      in the code later that will break this complex behavior.
      
      Or, simpler, we go back to initial behavior, which is: the program that
      did not crash does actually exit when the other crashes.
      
      This commit provides the second solution.
      
      It can easily be reverted whenever someone wants to implement the complex
      solution.
      1894bdb2
    • Cedric Roux's avatar
      fix: do NR only if at least one gNB is connected to the eNB · 94826057
      Cedric Roux authored
      We used to set 'does_nr' of an UE if we detect ENDC supported in the
      UE capabilities.
      
      Then we activate NR measurements if 'does_nr' is true.
      
      The problem is that if the eNB is not connected to a gNB but the UE
      reports some NR measurements (because a gNB is running somewhere near)
      then the eNB will crash when starting the switch to NR.
      
      A (quick) solution is to set 'does_nr' only if there is a gNB connected to
      the eNB.
      
      Maybe not the best solution. To be changed if needed.
      94826057
    • Remi Hardy's avatar
      Integration 2021 wk13 c · 57200249
      Remi Hardy authored
      MR !1092: Nr pdcp nia2 integrity
      This code has not been tested with a COTS UE. We need SRB1/2 (so we need SA) to test.
      The activation of security and integrity for SRB1 will need more code (new functions) because it happens after some time, not at creation time of the PDCP entity and there is no way to do this with current code.
       
      MR !1075: Fft bench hotfix 
      Simple fix to make the FFT testbench compile and run on current develop.
      
      MR !1083: NR power measurement fixes
      57200249
  2. 30 Mar, 2021 7 commits
  3. 29 Mar, 2021 8 commits
  4. 28 Mar, 2021 2 commits
  5. 25 Mar, 2021 2 commits
  6. 23 Mar, 2021 1 commit
  7. 22 Mar, 2021 5 commits
  8. 21 Mar, 2021 1 commit
  9. 20 Mar, 2021 1 commit
  10. 19 Mar, 2021 10 commits