Commit 0a0cd884 authored by Robert Schmidt's avatar Robert Schmidt

Remove all references to CatM

parent 208a15aa
This diff is collapsed.
...@@ -307,7 +307,7 @@ def GetParametersFromXML(action): ...@@ -307,7 +307,7 @@ def GetParametersFromXML(action):
#CiTestObj.air_interface = 'ocp-enb' #CiTestObj.air_interface = 'ocp-enb'
logging.error('OCP UE -- NOT SUPPORTED') logging.error('OCP UE -- NOT SUPPORTED')
elif (action == 'Ping') or (action == 'Ping_CatM_module'): elif action == 'Ping':
CiTestObj.ping_args = test.findtext('ping_args') CiTestObj.ping_args = test.findtext('ping_args')
CiTestObj.ping_packetloss_threshold = test.findtext('ping_packetloss_threshold') CiTestObj.ping_packetloss_threshold = test.findtext('ping_packetloss_threshold')
ue_id = test.findtext('id') ue_id = test.findtext('id')
...@@ -713,12 +713,6 @@ elif re.match('^InitiateHtml$', mode, re.IGNORECASE): ...@@ -713,12 +713,6 @@ elif re.match('^InitiateHtml$', mode, re.IGNORECASE):
if foundCount != HTML.nbTestXMLfiles: if foundCount != HTML.nbTestXMLfiles:
HTML.nbTestXMLfiles=foundCount HTML.nbTestXMLfiles=foundCount
if (CiTestObj.ADBIPAddress != 'none') and (CiTestObj.ADBIPAddress != 'modules'):
terminate_ue_flag = False
CiTestObj.GetAllUEDevices(terminate_ue_flag)
CiTestObj.GetAllCatMDevices(terminate_ue_flag)
HTML.htmlNb_Smartphones=len(CiTestObj.UEDevices)
HTML.htmlNb_CATM_Modules=len(CiTestObj.CatMDevices)
HTML.CreateHtmlHeader(CiTestObj.ADBIPAddress) HTML.CreateHtmlHeader(CiTestObj.ADBIPAddress)
elif re.match('^FinalizeHtml$', mode, re.IGNORECASE): elif re.match('^FinalizeHtml$', mode, re.IGNORECASE):
logging.info('\u001B[1m----------------------------------------\u001B[0m') logging.info('\u001B[1m----------------------------------------\u001B[0m')
...@@ -816,7 +810,6 @@ elif re.match('^TesteNB$', mode, re.IGNORECASE) or re.match('^TestUE$', mode, re ...@@ -816,7 +810,6 @@ elif re.match('^TesteNB$', mode, re.IGNORECASE) or re.match('^TestUE$', mode, re
if (CiTestObj.ADBIPAddress != 'none') and (CiTestObj.ADBIPAddress != 'modules'): if (CiTestObj.ADBIPAddress != 'none') and (CiTestObj.ADBIPAddress != 'modules'):
terminate_ue_flag = False terminate_ue_flag = False
CiTestObj.GetAllUEDevices(terminate_ue_flag) CiTestObj.GetAllUEDevices(terminate_ue_flag)
CiTestObj.GetAllCatMDevices(terminate_ue_flag)
elif (CiTestObj.ADBIPAddress == 'modules'): elif (CiTestObj.ADBIPAddress == 'modules'):
CiTestObj.UEDevices.append('COTS-Module') CiTestObj.UEDevices.append('COTS-Module')
else: else:
...@@ -911,16 +904,6 @@ elif re.match('^TesteNB$', mode, re.IGNORECASE) or re.match('^TestUE$', mode, re ...@@ -911,16 +904,6 @@ elif re.match('^TesteNB$', mode, re.IGNORECASE) or re.match('^TestUE$', mode, re
CiTestObj.InitializeOAIUE(HTML,RAN,EPC,COTS_UE,InfraUE,CONTAINERS) CiTestObj.InitializeOAIUE(HTML,RAN,EPC,COTS_UE,InfraUE,CONTAINERS)
elif action == 'Terminate_OAI_UE': elif action == 'Terminate_OAI_UE':
CiTestObj.TerminateOAIUE(HTML,RAN,COTS_UE,EPC,InfraUE,CONTAINERS) CiTestObj.TerminateOAIUE(HTML,RAN,COTS_UE,EPC,InfraUE,CONTAINERS)
elif action == 'Initialize_CatM_module':
CiTestObj.InitializeCatM(HTML)
elif action == 'Terminate_CatM_module':
CiTestObj.TerminateCatM(HTML)
elif action == 'Attach_CatM_module':
CiTestObj.AttachCatM(HTML,RAN,COTS_UE,EPC,InfraUE,CONTAINERS)
elif action == 'Detach_CatM_module':
CiTestObj.TerminateCatM(HTML)
elif action == 'Ping_CatM_module':
CiTestObj.PingCatM(HTML,RAN,EPC,COTS_UE,EPC,InfraUE,CONTAINERS)
elif action == 'Ping': elif action == 'Ping':
CiTestObj.Ping(HTML,RAN,EPC,COTS_UE, InfraUE, CONTAINERS) CiTestObj.Ping(HTML,RAN,EPC,COTS_UE, InfraUE, CONTAINERS)
elif action == 'Iperf': elif action == 'Iperf':
......
...@@ -31,11 +31,6 @@ ...@@ -31,11 +31,6 @@
- Terminate_SPGW - Terminate_SPGW
- Initialize_5GCN - Initialize_5GCN
- Terminate_5GCN - Terminate_5GCN
- Initialize_CatM_module
- Terminate_CatM_module
- Attach_CatM_module
- Detach_CatM_module
- Ping_CatM_module
- IdleSleep - IdleSleep
- Perform_X2_Handover - Perform_X2_Handover
- Build_Image - Build_Image
......
...@@ -25,16 +25,10 @@ ...@@ -25,16 +25,10 @@
<htmlTabName>EPC-Closure</htmlTabName> <htmlTabName>EPC-Closure</htmlTabName>
<htmlTabIcon>log-out</htmlTabIcon> <htmlTabIcon>log-out</htmlTabIcon>
<TestCaseRequestedList> <TestCaseRequestedList>
040202
050201 060201 070201 050201 060201 070201
</TestCaseRequestedList> </TestCaseRequestedList>
<TestCaseExclusionList></TestCaseExclusionList> <TestCaseExclusionList></TestCaseExclusionList>
<testCase id="040202">
<class>Terminate_CatM_module</class>
<desc>Terminate CAT-M Module</desc>
</testCase>
<testCase id="050201"> <testCase id="050201">
<class>Terminate_HSS</class> <class>Terminate_HSS</class>
<desc>Terminate HSS</desc> <desc>Terminate HSS</desc>
......
...@@ -28,8 +28,7 @@ ...@@ -28,8 +28,7 @@
<TestUnstable>True</TestUnstable> <TestUnstable>True</TestUnstable>
<TestCaseRequestedList> <TestCaseRequestedList>
030201 030201
040102 030121 000001 000001 000001 040402 000001 030201
030121 000001 040302 000001 040502 000001 040402 040202 000001 030201
</TestCaseRequestedList> </TestCaseRequestedList>
<TestCaseExclusionList> <TestCaseExclusionList>
</TestCaseExclusionList> </TestCaseExclusionList>
...@@ -51,31 +50,4 @@ ...@@ -51,31 +50,4 @@
<desc>Terminate eNB</desc> <desc>Terminate eNB</desc>
</testCase> </testCase>
<testCase id="040102">
<class>Initialize_CatM_module</class>
<desc>Initialize CAT-M Module</desc>
</testCase>
<testCase id="040202">
<class>Terminate_CatM_module</class>
<desc>Terminate CAT-M Module</desc>
</testCase>
<testCase id="040302">
<class>Attach_CatM_module</class>
<desc>Attach CAT-M Module</desc>
</testCase>
<testCase id="040402">
<class>Detach_CatM_module</class>
<desc>Detach CAT-M Module</desc>
</testCase>
<testCase id="040502">
<class>Ping_CatM_module</class>
<desc>ping (10MHz - 20 sec)</desc>
<ping_args>-c 20</ping_args>
<ping_packetloss_threshold>5</ping_packetloss_threshold>
</testCase>
</testCaseList> </testCaseList>
...@@ -108,28 +108,6 @@ ...@@ -108,28 +108,6 @@
<desc>Reboot UE</desc> <desc>Reboot UE</desc>
</testCase> </testCase>
<!-- CAT-M UE class command references -->
<testCase id="040102">
<class>Initialize_CatM_module</class>
<desc>Initialize CAT-M Module</desc>
</testCase>
<testCase id="040202">
<class>Terminate_CatM_module</class>
<desc>Terminate CAT-M Module</desc>
</testCase>
<testCase id="040302">
<class>Attach_CatM_module</class>
<desc>Attach CAT-M Module</desc>
</testCase>
<testCase id="040402">
<class>Detach_CatM_module</class>
<desc>Detach CAT-M Module</desc>
</testCase>
<!-- EPC class command references --> <!-- EPC class command references -->
<testCase id="050101"> <testCase id="050101">
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment