Commit 0295caa9 authored by Boris Djalal's avatar Boris Djalal

Iperf DL seems to be working.

Signed-off-by: default avatarBoris Djalal <boris.djalal@eurecom.fr>
parent d6dd4c25
......@@ -212,25 +212,55 @@ function check_ping_result {
}
function iperf_dl {
echo $@
local REQ_BANDWIDTH=$5
local BASE_LOG_FILE=$6
echo "echo \"iperf -u -s -i 1\"" > $1
echo "echo \"COMMAND IS: iperf -u -s -i 1\" > tmp/cmake_targets/log/${BASE_LOG_FILE}_server.txt" > $1
echo "nohup iperf -u -s -i 1 >> tmp/cmake_targets/log/${BASE_LOG_FILE}_server.txt &" >> $1
ssh -o StrictHostKeyChecking=no ubuntu@$2 < $1
cat $1
rm $1
echo "echo \"iperf -c $UE_IP_ADDR -u -t 30 -b ${REQ_BANDWIDTH}M -i 1\"" > $3
echo "echo \"COMMAND IS: iperf -c $UE_IP_ADDR -u -t 30 -b ${REQ_BANDWIDTH}M -i 1\" > ${BASE_LOG_FILE}_client.txt" > $3
echo "iperf -c $UE_IP_ADDR -u -t 30 -b ${REQ_BANDWIDTH}M -i 1 | tee -a ${BASE_LOG_FILE}_client.txt" >> $3
ssh -o StrictHostKeyChecking=no ubuntu@$4 < $3
cat $3
rm -f $3
echo "killall --signal SIGKILL iperf" >> $1
ssh -o StrictHostKeyChecking=no ubuntu@$2 < $1
cat $1
rm $1
}
function nos1_iperf {
# nos1_iperf $REAL_SERVER_IP_ADDRESS $VM_SERVER_IP_ADDRESS $VM_SERVER_CMDS $VM_CLIENT_IP_ADDRESS $VM_CLIENT_CMDS bandwitch log_file
echo $@
local REAL_SERVER_IP_ADDRESS=$1
local REQ_BANDWIDTH=$6
local BASE_LOG_FILE=$7
echo "echo \"iperf -u -s -i 1\"" > $3
echo "echo \"COMMAND IS: iperf -u -s -i 1\" > tmp/cmake_targets/log/${BASE_LOG_FILE}_server.txt" > $3
echo "nohup iperf -u -s -i 1 >> tmp/cmake_targets/log/${BASE_LOG_FILE}_server.txt &" >> $3
ssh -o StrictHostKeyChecking=no ubuntu@$2 < $3
cat $3
rm $3
echo "echo \"iperf -c $REAL_SERVER_IP_ADDRESS -u -t 30 -b ${REQ_BANDWIDTH}M -i 1\"" > $5
echo "echo \"COMMAND IS: iperf -c $UE_IP_ADDR -u -t 30 -b ${REQ_BANDWIDTH}M -i 1\" > ${BASE_LOG_FILE}_client.txt" > $5
echo "iperf -c $REAL_SERVER_IP_ADDRESS -u -t 29 -b ${REQ_BANDWIDTH}M -i 1 | tee -a ${BASE_LOG_FILE}_client.txt" >> $5
ssh -o StrictHostKeyChecking=no ubuntu@$4 < $5
cat $5
rm -f $5
echo "killall --signal SIGKILL iperf" >> $3
ssh -o StrictHostKeyChecking=no ubuntu@$2 < $3
cat $3
rm $3
}
function iperf_ul {
local REQ_BANDWIDTH=$5
local BASE_LOG_FILE=$6
......@@ -436,7 +466,7 @@ function start_nos1_sim_ue {
echo "egrep -c \"Generating RRCConnectionReconfigurationComplete\" /home/ubuntu/tmp/cmake_targets/log/$LOC_LOG_FILE" > $LOC_UE_VM_CMDS
cat $LOC_UE_VM_CMDS
local i="0"
while [ $i -lt 10 ]
while [ $i -lt 30 ]
do
RESPONSE=`ssh -o StrictHostKeyChecking=no ubuntu@$LOC_UE_IP_ADDR < $LOC_UE_VM_CMDS`
if [ $RESPONSE -ne 0 ]
......@@ -1529,6 +1559,8 @@ function run_test_on_vm {
if [[ "$RUN_OPTIONS" == "complex" ]] && [[ $VM_NAME =~ .*-ethernet.* ]]
then
PING_STATUS=0
IPERF_STATUS=0
if [ -d $ARCHIVES_LOC ]
then
rm -Rf $ARCHIVES_LOC
......@@ -1600,10 +1632,6 @@ function run_test_on_vm {
echo "Pinging the eNB from the UE"
echo "############################################################"
PING_LOG_FILE=fdd_05MHz_ping_enb.txt
echo "UE_VM_CMDS = $UE_VM_CMDS"
echo "UE_VM_IP_ADDR = $UE_VM_IP_ADDR"
echo "UE_IP_ADDR = $UE_IP_ADDR"
echo "PING_LOG_FILE = $PING_LOG_FILE"
ping_nos1_enb_ip_addr $UE_VM_CMDS $UE_VM_IP_ADDR $ENB_REAL_IP_ADDR $PING_LOG_FILE
#ping_ue_ip_addr $UE_CMDS $UE_VM_IP_ADDR $REAL_UE_IP_ADDR $PING_LOG_FILE
scp -o StrictHostKeyChecking=no ubuntu@$UE_VM_IP_ADDR:/home/ubuntu/$PING_LOG_FILE $ARCHIVES_LOC
......@@ -1612,6 +1640,18 @@ function run_test_on_vm {
echo "END OF Pinging the eNB from the UE"
echo "############################################################"
echo "############################################################"
echo "Iperf DL (the server is the UE and the client is the eNB)"
echo "############################################################"
CURR_IPERF_LOG_BASE=fdd_05MHz_iperf_dl
nos1_iperf $UE_REAL_IP_ADDR $UE_VM_IP_ADDR $UE_VM_CMDS $ENB_VM_IP_ADDR $ENB_VM_CMDS 1 $CURR_IPERF_LOG_BASE
scp -o StrictHostKeyChecking=no ubuntu@$ENB_VM_IP_ADDR:/home/ubuntu/${CURR_IPERF_LOG_BASE}_client.txt $ARCHIVES_LOC
scp -o StrictHostKeyChecking=no ubuntu@$UE_VM_IP_ADDR:/home/ubuntu/tmp/cmake_targets/log/${CURR_IPERF_LOG_BASE}_server.txt $ARCHIVES_LOC
check_iperf $ARCHIVES_LOC/$CURR_IPERF_LOG_BASE 1
echo "############################################################"
echo "END OF Iperf DL"
echo "############################################################"
echo "############################################################"
echo "Stopping the UE in FDD-5MHz mode"
echo "############################################################"
......
Markdown is supported
0%
or
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment